Split Case Type KP (Horizontal Split Case) Type KPV (Vertical Split Case) Type KPVS (Vertical Split-coupled Split Case) The PACO KP/KPV split case pump is a single-stage, non-self-priming, between bearing, centrifugal volute pump. The axially split design allows easy removal of the top casing and access to the pump components (bearings, wear rings, impeller, and shaft seal) without disturbing the motor or pipe work. The independent bearing housing allows for ease of maintenance without removing the top casing. The double volute design reduces the radial load on the shaft, extending component life, minimizing vibration and providing quiet operation. The KP/KPV pump also offers high pump efficiencies throughout the range.
› Paco pump serial number search › Paco pump model numbers › Paco pump catalog › Paco pump parts breakdown diagram › Paco pump parts manual › Paco pump parts breakdown › Paco pumps manual. Grundfos Express Suite ~ Contact Information. The PUMP MODEL AND SERIAL NUMBER should be referenced when-ever any replacement parts kit is ordered, while the PUMP CONDITIONS (GPM/TDH) and IMPELLER TRIM are REQUIRED data for the ordering of re-placement impellers. PACO PUMPS Supercedes 8/05. PACO PUMPS 4015.
High energy efficiency along with long pump life and easy maintenance add up to low life-cycle costs. The KP/KPV pump is ideal for custom applications and is available in a wide range of variants. The high efficiency and low life cycle costs make the KP/KPV ideal for any commercial building, water utility or industrial projects. The KPV pump is available with a liquid cooled sleeve bearing which promotes longer life and reduces maintenance.
The KPVS split-coupled split case pump reduces the mechanical space footprint with its vertical motor arrangement, provides easy access to seal and internal components without ever needing to remove the motor, and needs no field alignment. The new KPVS also includes all the benefits of a double suction/double volute splitcase design – reduced radial loads mean less noise and vibration while the between bearing design is more robust and greatly reduces vibration.
Read A1b.2 Pages 1-9 Dated 3-01-06.pmd text version A1b.2 4/06 Supercedes 8/05 PACO PUMPS PACO PUMPS CAT#: STOCK#: SER#: GPM: TDH: IMP. DIA: END SUCTION PUMPS REPLACEMENT PARTS GUIDE While PACO End Suction Pumps are designed and built to provide maximum life while requiring minimum attention and service, replacement parts may at times be required. VIRTUALLY ALL REQUIRED PARTS ARE AVAILABLE IN KIT FORM. These kits (easily selected from the charts on the following pages) have been designed to insure that any parts needed when replacing any End Suction component, are furnished when you need them, with minimum effort. Here are some guidelines and suggestions: GENERAL NOTES: The pump nameplate contains all data required in the selection and ordering of the proper replacement parts kit. The PUMP MODEL AND SERIAL NUMBER should be referenced whenever any replacement parts kit is ordered, while the PUMP CONDITIONS (GPM/TDH) and IMPELLER TRIM are REQUIRED data for the ordering of replacement impellers.
NOTE: SEAL/PACKING KITS ARE ALWAYS RECOMMENDED AS SPARE PARTS To replace a mechanical seal. Select the correct Seal Kit, which contains all gaskets and impeller hardware. Shaft sleeve inspection is suggested. To replace the packing Select the correct Packing Kit, which contains all gaskets, impeller hardware and lantern ring. If the packing gland is damaged it may be replaced by ordering the proper Gland Kit. A shaft sleeve or adapter shaft will probably be required. To replace the shaft sleeves.
Select sleeve from sleeve chart. A Seal or Packing Kit will provide other normally needed parts.
NOTE:For close-coupled units, motor frame type is required for proper sleeve replacement. Motor type is indicated by frame designation, found on motor nameplate: Gyropoise Motors - Frame XXX TG JM Motors - Frame XXX JM or JMZ CCP Motors - All Others (Fractional construction X0XXXX and X1XXXX do not require sleeves.) To replace the Bearing Frame.Select the correct Bearing Frame assembly.
To replace impeller.Select the correct Impeller Kit which contains all gaskets and impeller hardware. A Wear Ring Kit is highly recommended, and a Seal or Packing Kit will probably be required.
1 A1b.2 4/06 Supercedes 8/05 Shaft sleeve inspection is suggested. To replace wear rings. Select the correct Wear Ring Kit.
An Impeller Kit may be indicated if wear is excessive. A Seal/Packing Kit will provide all other normally replaced components.
To replace bearings. (Frame mounted pumps only.) Select the correct Bearing Frame Kit, which contains the bearings and moisture seals. To replace the shaft. Select the correct Shaft Kit. A Bearing Frame Kit and shaft sleeve will also be required.
A Seal or Packing Kit will probably be required. PACO PUMPS To replace lost/damaged hardware.
Select the correct Hardware Kit. To overhaul the pump. Select an Impeller Kit, Wear Ring Kit, Hardware Kit, Seal or Packing Kit, and a Sleeve or Adapter Shaft.
Bearing replacement may also be indicated. To overhaul the bearing frame. Select a Bearing Frame Kit and a Shaft Kit. To replace slinger. (Included in Shaft Kit) If not replacing shaft, order individually. ORDERING: After determining and selecting the required Kit(s), or for selection assistance, contact your local PACO Sales Office, Representative or Distributor. 2 A1b.2 4/06 Supercedes 8/05 Pump Pump Model Constr.